FL16 WATER FLOW LOGGERS
- Compact, self-powered and easy to use
- No confined space entry required for sensor deployment
- User friendly Windows and PDA software included
- USB and Serial communication options available
- PDA software simplifies field data collection
- User programmable start and stop alarms, engineering units, and field calibration setup
- Wet-wet transducer eliminates vent tube concerns
Listing Details
The AK1500 Bluetooth Adaptor was designed to eliminate the need for custom PDA cables to communicate between your PDA and the FL16 Water Flow Loggers. The adaptor connects to the Water Flow Logger's serial port using the same interface cable provided with the software-cable kit. The interface operates from a single 9 volt battery and is turned on automatically when the cable connects the water flow logger and Bluetooth adapter. Because the Bluetooth module consumes power when turned on, it is recommended that the cable be disconnected from the water flow logger when not in use. A red LED shows the power status and is on continuously while the adaptor is plugged into the water flow logger. There is also a blue LED that shows the status of the Bluetooth connection. |
FL16 Water Flow Loggers Memory: Non-volatile flash memory Power: Two 9VDC Alkaline Batteries Battery Life: Up to 1 year (depending on recording intervals) Resolution: 12 bit Moisture Protection: Silicon coating (prevents damage to electronics from condensation) Temperature: -40° to +185°F (-40° to +85°C) Humidity: 0-95% non-condensing Storage Capacity: 81,759 time and date stamped data points including battery voltage Sample Modes: High Speed (10 samples per second), Fixed Interval (Programmable from 1 sec to >1 year), Logarithmic, Exception Data Overwrite: Select memory wrap or unwrap (unwrap will stop logging data once memory is full) Clock: Synchronizes to the time and date of user's computer Clock Accuracy: 0.0025% or 1 minute in 1 month Clock Format: Month/Day/Year Hour/Minute/Second Enclosure: 1-7/8 inch dia x 11-1/2 inch length (fits inside a 2" well), stainless steel UV protected PVC vented for barometric pressure compensation Weight: 1.6 lbs (0.7 kg) (with battery and 25' cable) Communication Port: FL16S: RS-232 4-pin circular connector FL16U: USB Type B Selectable Baud Rates: 9600,19200,28800,38400,57600,115200 Global Water Flow Loggers Software Compatible with Microsoft's Windows 98, ME, 2000, NT, XP, Vista, and 7 Windows and Excel are trademarks of the Microsoft Corporation Tabular Display/Printout Data in standard spreadsheet format (.CSV) Programmable alarm start and stop times Field calibration software and help files included Water Flow Logger Vented Cable Conductors: 4 each 22 AWG Material: Marine grade polyurethane jacket, HD polyethylene vent tube, full foil shield Shield: Aluminum Mylar Outside Diameter: 0.307 inch (7.8mm) Length: Standard 25' (up to 500' from factory) Temperature range: -22 to 185°F (-30° to 85°C) Weight: 0.7 oz/ft (65g/m) Water Flow Sensor Sensor Element: Silicone Diaphragm, Wet/Wet Transducer Level Range: 0-3 ft Temperature Range: 32-122°F (0-50°C) Linearity and Hysteresis: ±0.1% FS Accuracy: Level: ±0.1% FS at constant temperature, ±0.2% over 32° to 70°F (0° to 21.1°C) range Temperature: Smaller of 0.5°F or ±1% of reading Overpressure: 2 x full scale range Burst Pressure: 10 x full scale range Resolution: Infinite (Analog) Output Currents: Level: 4-20mA ±1mA of full scale Temperature: 0-10mA ±1mA full scale Supply Voltage: 10-36VDC Current Draw: Combined level and temperature output currents Warm Up Time: 3 seconds recommended Operating Temperature: 0° (not frozen) to +185°F (-17.8° to 85°C) Compensated Temperature Range: 32° to 70°F (0 to 21.1°C) submerged, automatic barometric compensation Housing: Material: 316 Stainless Steel Outer Sleeve, PVC diffuser and strain relief Size: 9 inch long x 1 inch dia. (22.9 cm long x 2.54 cm dia.) Weight: ~250g (9oz) Bluetooth Format: Bluetooth 2.0 SPP (Serial Port Protocol) Baud Rate: Auto Detect up to 115K Baud Power: 9 V Alkaline, approx. 20 hours continuous use Current: 30mA Average Range: 20 Feet Maximum Operating Temp: -40° to +185°F (-40° to +85°C) Compatible Software: Global Logger II version 2.1.5 or higher Global Logger II PDA software version 2.0.1 FL16 Flow Monitor version 2.3.2 |