MULTI 3400i MULTI-PARAMETER METERS

163.jpg
FEATURES:
  • Accurate, rugged and easy to use
  • Up to three parameters measured at once (including temperature)
  • Up to 2500 hours continuous operation
Rating
0 vote
Favoured:
0

Listing Details

Product Description
The compact precision Multi 3400i Multi-parameter Meters enable you to carry out pH measurements, dissolved oxygen (DO) measurements and conductivity measurements quickly and reliably.  The Multi 3400i Multi-parameter Meters provide the maximum degree of operating comfort, reliability and measuring certainty for all applications.  The multi-parameter meter is hose-proof with battery or optional AC adapter and is optimally suited for use in the field, in laboratories, or at production sites. The Multi 3400i Multi-parameter Meters have several useful features including an energy saving feature to avoid unnecessary battery depletion.  The energy saving feature switches the multi-parameter meter off if no key has been pressed for an hour.  The multi-parameter meter can perform pH measurements with or without a temperature sensor or by using the conductivity or oxygen probe's built in temperature sensor.  The multi-parameter meters recognize which sensors are connected and automatically switch to the correct mode for the temperature measurement.  The multi-parameter meter's AutoRead function (drift control) checks the stability of the measurement signal. pH/Oxi or pH/Cond Multi-parameter Meters
WTW multi-parameter meters stand for precise multi-parameter measuring technology.  The pH/Oxi 3400i multi-parameter meter for the determination of pH, oxygen and temperature and the pH/Cond 3400i multi-parameter meter for the determination of pH, conductivity and temperature are favorably-priced alternatives to the single parameter instruments for applications which require the measurement of several parameters.  The multi-parameter meters are hose-proof and also meet the requirements of IP 66.  Kits include a professional case with sample beakers, multi-parameter meter, pH electrode and oxygen or conductivity sensor, STH 320 stand and calibration and maintenance supplies. TetraCon® 325 Conductivity Probe
The TetraCon® 4-electrode system sets a new standard for professional conductivity measurements.  In comparison with conventional measuring cells with 2 electrodes, the TetraCon® 325 conductivity cell offers numerous technical advantages:
  • Highly accurate and linear because of optimized cell geometry
  • Extremely large measuring range with just one cell
  • Long-term cell constant stability with high-quality abrasion-resistant graphite electrodes
  • Built-in temperature sensor as standard
  • Smallest immersion depth possible
  • Automatic resistance compensation provides accurate measurements even with a dirty electrode
  • Measurement not affected by cable influences, polarization effects or contact with side walls
  • Robust, unbreakable epoxy body
Specification
  pH/ORP measurement Oxygen measurement Conductivity measurement
Range/Resolution pH:
     -2.00 to 19.99 / 0.01
mV:
     -1999 to +1999 / 1
Temp.:
     23 to 221 °F (-5.0 to 105.0 °C) / 0.1 (0.1)
O2 Concentration:
     0.00 to 19.99 mg/l / 0.01
     0.0 to 90.0 mg/l / 0.1
O2 Saturation:
     0.00 to 199.9% / 0.1
     0.0 to 600% / 1
Temp:
     32 to 122 °F (0.0 to 50.0 °C) / 0.1 (0.1)
Conductivity:
     0 to 1999 uS/cm / 1
     0.00 to 19.99 mS/cm / 0.01
     0.0 to 199.9 mS/cm / 0.1
     0 to 500 mS/cm / 1
Salinity:
     0.0 to 70.0 according to the IOT table / 0.1
Temp:
     23 to 221 °F (-5.0 to 105.0 °C) / 0.1 (0.1)
Accuracy (+ 1 Digit) pH:
     + 0.03 (+2 pH units around the calibration point)
mV: + 1
Temp: + 0.1
O2 Concentration:
     + 0.5 % of measured value at ambient temperature +41 to +86 °F (+5 to +30 °C)
O2 Saturation:
     + 0.5 % of measured value when measuring in the range of + 10 K around the calibration temperature
Temperature Compensation:
     
File

multi3400iB.pdf (652 views)