FM500 ULTRASONIC FLOW METERS

67.jpg
FEATURES:
  • Clean or dirty water applications with selectable modes
  • Quick and easy setup and operation
  • Clamp-on transducers never contact process liquid
  • Built in data logger downloads to standard SD card
  • Fully configurable analog and pulse outputs
Rating
0 vote
Favoured:
0

Listing Details

Product Description
The Global Water FM500 ultrasonic flow meters provide accurate and trouble free flow metering for a wide range full pipe applications including: potable water, raw wastewater, effluent, well water, slurries, or virtually any sound conducting liquid.  The FM500 ultrasonic flow meter incorporates the latest ultrasonic technology to give you an accurate, easy to use hybrid flow meter with selectable Doppler or transit-time operating modes.  With their quick and easy clamp-on transducer installation, factory pre-configuration and user programmable menu driven interface, the ultrasonic flow meters are a snap to commission in the field.  The reliable FM500 ultrasonic flow meters use custom algorithms and DSP technology to ensure high accuracy flow metering, and the proprietary AGC (Automatic Gain Control) algorithm eliminates the need for manual gain adjustments. Ultrasonic Flow Meter's Great Features
Loaded with the features, the FM500 ultrasonic flow meters include: five programmable and password protected configurations for multiple user and portable applications, an easy to read 320 x 240 pixel backlit LCD display, data logging to standard SD Card format (user configurable to time interval, flow rate and total set-point triggers), isolated 4-20mA analog and 0-1000Hz pulse outputs. Ultrasonic Flow Meter's Optional Features
Optional features include: three configurable relay outputs and a communications package that allows the ultrasonic flow meter to connect to your computer via RS-232, RS-485, USB or Ethernet.  The ultrasonic flow meter's communication package also permits remote access and control of all functions including real-time display, system configuration, data logging, remote data capture and process control functions.  The software included with the ultrasonic flow meter's communication package allows remote internet access through a local network set-up. Custom Configured Ultrasonic Flow Meters
The FM500 ultrasonic flow meters can be configured for your specific pipe and process liquid application so that it is ready to go out of the box.  We will need the following information for configuration purposes: Pipe size (ID), material and schedule (EG: 3 inch schedule 40 PVC)
Process liquid being measured (EG: raw wastewater)
Volumetric and time units to be displayed (EG: US gallons/minute)
Language displayed (EG: English) How The Ultrasonic Flow Meters Work
The Sonic-Pro series Hybrid Ultrasonic Flow Meters can measure fluid flow in virtually any fluid in which sound waves can travel.  The Ultrasonic Flow Meters are considered "hybrid" because they can measure fluid flow using either the Doppler or Transit Time methods.  The Sonic-Pro ultrasonic flow meter's sound transducers are clamped to the outside of the pipe wall and include no moving parts.  This method of flow measurement is safe, non-intrusive and very easy to service. The Ultrasonic Flow Meter's Doppler measurement method requires particles be present in the flow stream to "reflect" the sound waves.  The ultrasonic flow meter may not read flow correctly when using the Doppler mode if the fluid contains no particles. The Ultrasonic Flow Meter's Transit Time measuring method requires relatively "clean" fluid to enable the sound waves to complete their circuit.  The Ultrasonic Flow Meters may be operated in the Transit-Time mode when the fluid contains particles.  To allow for changes in the fluid's particle count, the Sonic-Pro Ultrasonic Flow Meters monitor the signal gain and employ an Automatic Gain Control (AGC) algorithm that periodically adjusts the gain to maintain the optimum power level. The speed at which sound travels in the fluid must be known.  The factory will configure the ultrasonic flow meter for a known fluid during the initial configuration.  The Sonic-Pro Ultrasonic Flow Meters include a 5-button user interface that can be used to configure the meter.  Many common fluids are listed in The Ultrasonic Flow Meter's software and can be selected directly from the menu.  Provided the speed of sound in the fluid is known, custom "unknown" fluids can be input into the ultrasonic flow meters manually by the user.  A list of various fluids and their sound speeds are provided in the ultrasonic flow meter's user manual.
Specification
Ultrasonic Flow Meters General
Measuring principle: Ultrasonic Doppler or transit time via pipe mounted transducers
Condition of flow: Full pipe within the minimum and maximum velocity specifications
Liquid types: Virtually any acoustically conductive fluid
Transit time mode: from 0% to 1% (0 to 10,000 ppm) particulate
Doppler mode: from 0.02% to 15% (200 to 150,000 ppm) of 100 micron particulate
Nominal pipe sizes: 0.5 inch - 12.0 inch (20mm to 315mm)
Pipe materials: Most metal and plastic pipes
Pipe liner materials: Most plastic liners
Liquid velocity range: 0 to 30 f/s (0 to 9 m/s)
Accuracy at pipe inside diameter:
     Flow rate averaging time (5.0s):
          +1% of rate >8 ft/s and +0.06 ft/s 1 ft/s and +0.01 ft/s 12 ft/s and +0.12 ft/s 5 ft/s and +0.05 ft/s 12 ft/s and +0.25 ft/s 12 ft/s and +0.25 ft/s